DTC B144F-13: Power Liftgate (Plug) Drive Unit Motor Circuit Malfunction [Power Liftgate (Plug) Control Module]: Notes
DTC B144F:13 (POWER LIFTGATE CONTROL MODULE) DETECTION CONDITION AND POSSIBLE CAUSE
| Description |
Power liftgate (PLUG) drive unit motor circuit malfunction |
| Detection condition |
- Power liftgate (PLUG) control module detected an open circuit in the power liftgate (PLUG) drive unit circuit for 8 s or more.
|
| Fail-safe |
- Stops the power liftgate (PLUG) system operation.
|
| Possible cause |
- Power liftgate (PLUG) drive unit (LH) connector or terminal malfunction
- Power liftgate (PLUG) drive unit (RH) connector or terminal malfunction
- Power liftgate (PLUG) control module connector or terminal malfunction
- Open circuit in wiring harness between the following terminals:
- Power liftgate (PLUG) drive unit (LH) terminal G-Power liftgate (PLUG) control module terminal 2A
- Power liftgate (PLUG) drive unit (LH) terminal H-Power liftgate (PLUG) control module terminal 2C
- Power liftgate (PLUG) drive unit (RH) terminal G-Power liftgate (PLUG) control module terminal 2E
- Power liftgate (PLUG) drive unit (RH) terminal H-Power liftgate (PLUG) control module terminal 2B
- Power liftgate (PLUG) drive unit (LH) malfunction
- Power liftgate (PLUG) drive unit (RH) malfunction
- Power liftgate (PLUG) control module malfunction
|
Courtesy of MAZDA MOTORS CORP.
|