Home >> Mazda >> 2019 >> CX-9 Signature >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> On-Board Diagnostic - Power Liftgate Control Module >> DTC B1495-55: Configuration Data Unmatched With Foot-Motion Detection Unit [Power Liftgate (Plug) Control Module] >> Diagnostic Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Procedure

DTC B1495:55 (POWER LIFTGATE CONTROL MODULE) DIAGNOSTIC PROCEDURE

Step Inspection Action
1 VERIFY IF OTHER DTCs DISPLAYED FOR POWER LIFTGATE (PLUG) CONTROL MODULE  Yes Replace the power liftgate (PLUG) control module, then go to step 7.
(See POWER LIFTGATE (PLUG) CONTROL MODULE REMOVAL/INSTALLATION .)
No Go to the next step.
2 VERIFY INSTRUMENT CLUSTER DTCs  Yes Repair the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [INSTRUMENT CLUSTER] .)
No Go to the next step.
3 INSPECT FOOT-MOTION DETECTION UNIT CIRCUIT FOR SHORT TO GROUND  Yes Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Foot-motion detection unit terminal 1C-Power liftgate (PLUG) control module terminal 1C

If there is a common connector: 
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
  • Repair or replace the malfunctioning part.

If there is no common connector: 
  • Repair or replace the wiring harness which has a short to ground.

Go to Step 7.
No Go to the next step.
4 INSPECT FOOT-MOTION DETECTION UNIT CIRCUIT FOR OPEN CIRCUIT 
  • Switch the ignition off.
  • Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  • Verify, that the foot-motion detection unit and power liftgate (PLUG) control module connectors are disconnected.
  • Inspect for continuity between the following terminals (wiring harness-side):
    • Foot-motion detection unit terminal 1C-Power liftgate (PLUG) control module terminal 1C
  • Is there continuity?
Yes Go to the next step.
No Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Foot-motion detection unit terminal 1C-Power liftgate (PLUG) control module terminal 1C

If there is a common connector: 
  • Determine the malfunctioning part by inspecting the No common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
  • Repair or replace the malfunctioning part.

If there is no common connector: 
  • Repair or replace the wiring harness which has an open circuit.

Go to Step 7.
5 INSPECT FOOT-MOTION DETECTION UNIT CIRCUIT FOR SHORT TO POWER SUPPLY  Yes Go to next step.
No Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Foot-motion detection unit terminal 1C-Power liftgate (PLUG) control module terminal 1C

If there is a common connector: 
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
  • Repair or replace the malfunctioning part.

If there is no common connector: 
  • Repair or replace the wiring harness which has a short to power supply.

Go to Step 7.
6 RESET INSTRUMENT CLUSTER CONFIGURATION DATA  Yes Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.
(See INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA) .)
No Go to Step 9.
7 VERIFY THAT REPAIRS HAVE BEEN COMPLETED  Yes Replace the foot-motion detection unit, then go to the next step.
(See FOOT-MOTION DETECTION UNIT REMOVAL/INSTALLATION .)
No Go to the next step.
8 VERIFY THAT REPAIRS HAVE BEEN COMPLETED  Yes Replace the power liftgate (PLUG) control module, then go to the next step.
(See POWER LIFTGATE (PLUG) CONTROL MODULE REMOVAL/INSTALLATION .)
No Go to the next step.
9 VERIFY IF OTHER DTCs DISPLAYED 
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [POWER LIFTGATE (PLUG) CONTROL MODULE] .)
No DTC troubleshooting completed.