Home >> Mazda >> 2019 >> CX-9 Signature >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> On-Board Diagnostic - Power Liftgate Control Module >> DTC U2100-56: Power Liftgate (Plug) Control Module Configuration Not Completed [Power Liftgate (Plug) Control Module] >> Diagnostic Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Procedure

DTC U2100:56 (POWER LIFTGATE CONTROL MODULE) DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 VERIFY INSTRUMENT CLUSTER DTCs Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [INSTRUMENT CLUSTER] .)
No Go to the next step.
2 VERIFY IF MALFUNCTIONING LOCATION IS INSTRUMENT CLUSTER DEPENDING ON REPEATABILITY Yes Replace the instrument cluster, then go to the next step.
(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .)
No Go to the next step.
3 VERIFY THAT REPAIRS HAVE BEEN COMPLETED Yes Replace the power liftgate (PLUG) control module, then go to the next step.
(See POWER LIFTGATE (PLUG) CONTROL MODULE REMOVAL/INSTALLATION .)
No Go to the next step.
4 VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [POWER LIFTGATE (PLUG) CONTROL MODULE] .)
No DTC troubleshooting completed.