LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2019 >> CX-9 Signature >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> On-Board Diagnostic - 360DEGREES View Monitor Control Module >> DTC U0423-00: Error Signal Received From Instrument Cluster [360°View Monitor Control Module] >> Diagnostic Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Procedure

DTC U0423:00 (360° VIEW MONITOR CONTROL MODULE) DIAGNOSTIC PROCEDURE

Step Inspection Action
1 VERIFY OTHER 360°VIEW MONITOR CONTROL MODULE DTCs
  • Is DTC U3000:41 or U3000:49 displayed?
Yes Replace the 360°view monitor control module, then go to Step 4.
(See 360° VIEW MONITOR CONTROL MODULE REMOVAL/INSTALLATION .)
No Go to the next step.
2 VERIFY INSTRUMENT CLUSTER DTCs
  • Are any DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [INSTRUMENT CLUSTER] .)
No Go to the next step.
3 VERIFY IF MALFUNCTIONING LOCATION IS INSTRUMENT CLUSTER DEPENDING ON REPEATABILITY
  • Is the same Pending DTC present?
Yes Replace the instrument cluster, then go to the next step.
(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .)
No Go to Step 5.
4 VERIFY THAT REPAIRS HAVE BEEN COMPLETED
  • Is the same Pending DTC present?
Yes Repeat the inspection from Step 1.
Go to the next step.
No Go to the next step.
5 VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [360°VIEW MONITOR CONTROL MODULE] .)
No DTC troubleshooting completed.