LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2021 >> 6 Sport >> Repair and Diagnosis >> External Pages >> Different car >> Section 120 (On-Board Diagnostic - Position Memory Control Module) >> DTC B1B89-13: Slide Motor And Position Sensor Circuit Malfunction >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC B1B89-13: Slide Motor And Position Sensor Circuit Malfunction: Notes

WARNING: This page is about a different car, the 2018 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
DTC B1B89:13 (POSITION MEMORY CONTROL MODULE) DETECTION CONDITION AND POSSIBLE CAUSE

Description Slide Motor And Position Sensor Circuit Malfunction
Detection condition
  • Position memory control module detects the following conditions during the slide motor operation control:
    • Detects 4 times that current flowing to the slide motor is less than 1A.
      • Detects for 0.2 s that there is no change in the slide sensor pulse.
  • Position memory control module detects 4 times that current flowing to the slide motor exceeds 1 A.
  • Position memory control module detects for 5 s that there is no change in the slide sensor pulse during the slide motor operation control.
Fail-safe
  • Memory clearing:
    • If there is a malfunction in the slide position sensor, clear; memory positions.
  • Memory seat positioning using position memory switch and remote transmitter:
    • If there is a malfunction in the slide position sensor, inhibits all memory seat positioning.
      • If there is a malfunction in the slide motor, inhibits slide motor seat positioning.
  • Slide motor seat positioning using power seat switch:
    • If there is a malfunction in the slide motor, inhibits slide motor seat positioning.
  • Memory registration using position memory switch and remote transmitter:
    • If there is a malfunction in the slide position sensor, inhibits the memory registration.
      • If there is a malfunction in the slide motor and the malfunction is caused by short circuit, inhibits the memory registration.
Possible cause
  • Slide motor and position sensor connector or terminal malfunction
  • Position memory control module connector or terminal malfunction
  • Short to ground in wiring harness between the following terminals:
    • Position memory control module terminal 3A-Slide motor and position sensor terminal D
    • Position memory control module terminal 3B-Slide motor and position sensor terminal B
    • Position memory control module terminal 31-Slide motor and position sensor terminal F
      • Position memory control module terminal 3J-Slide motor and position sensor terminal H
  • Short to power supply in wiring harness between the following terminals:
    • Position memory control module terminal 3A-Slide motor and position sensor terminal D
    • Position memory control module terminal 3B-Slide motor and position sensor terminal B
    • Position memory control module terminal 31-Slide motor and position sensor terminal F
      • Position memory control module terminal 3J-Slide motor and position sensor terminal H
  • Open circuit in wiring harness between the following terminals:
    • Position memory control module terminal 3A-Slide motor and position sensor terminal D
    • Position memory control module terminal 3B-Slide motor and position sensor terminal B
    • Position memory control module terminal 31-Slide motor and position sensor terminal F
      • Position memory control module terminal 3J-Slide motor and position sensor terminal H
  • Front seat cushion frame/adjuster unit malfunction
    • Slide motor and position sensor malfunction
  • Position memory control module malfunction
G12235884