PID/Data Monitor Table [Power Liftgate (PLG) Control Module]

WARNING: This page is about a different car, the 2017 Mazda CX-5. However, it is still accessible from the selected car via links, so may be relevant.

-: Not applicable

PID Unit/Operation Data contents Module control terminal
BG_ST DEAD/INITIAL/PRE ARMING/ARMING/ARMING SB/ALARM/ALARM SB
  • DEAD: Ignition is in ACC or ON (engine off) and alarm cannot be activate d.
  • INITIAL: Ignition is switched OFF and transition to arming stand-by status is possible.
  • PRE ARMING: Transition period to arming status.
  • ARMING: Alarm can be activate d by inputting alarm trigger.
  • ARMING SB: Liftgate is open under arming status.
  • ALARM: Alarm trigger is input and alarm is activate d.
  • ALARM SB: After alarm activation finished, standing by for next alarm trigger input.
  • 1A (CAN_L)
  • 1B (CAN_H)
CLM_CL_CV Off/On
  • Off: Liftgate lock actuator close is not operating.
  • On: Liftgate lock actuator close is operating.
  • 2G (Closure motor (Open))
  • 2J (Closure motor (Closed))
CLM_CL_V V Displays the voltage during a close operation of the liftgate lock actuator. -
CLM_CUR A Displays the current during liftgate lock actuator operation.
  • 2G (Closure motor (Open))
  • 2J (Closure motor (Closed))
CLM_OP_CV Off/On
  • Off: Liftgate lock actuator open is not operating.
  • On: Liftgate lock actuator open is operating.
  • 2G (Closure motor (Open))
  • 2J (Closure motor (Closed))
CLM_OP_V V Displays the voltage during a open operation of the liftgate lock actuator. -
CTS_SW Off/On
  • Off: Liftgate is closed. (Liftgate latch switch is off.)
  • On: Liftgate is open. (Liftgate latch switch is on.)
1S (Liftgate condition)
DL_ST Lock/Unlock
  • Lock: Door/lift gate is locked.
  • Unlock: Door/lift gate is unlocked.
  • 1A (CAN_L)
  • 1B (CAN_H)
FL_SW Off/On
  • Off: Full latch switch is off.
  • On: Full latch switch is on.
1O (Full latch switch)
GT_SW Off/On
  • Off: Power liftgate (PLG) rear switch is not pressed.
  • On: Power liftgate (PLG) rear switch is pressed.
1AF (Power liftgate (PLG) rear switch signal)
HAND_S W Off/On
  • Off: Liftgate opener switch is not pressed.
  • On: Liftgate opener switch is pressed.
1Z (Liftgate opener switch signal)
HL_SW Off/On
  • Off: Half latch switch is off.
  • On: Half latch switch is on.
1Q (Half latch switch)
IG_STATUS Off/On
  • Off: Ignition is switched to ACC or OFF.
  • On: Ignition is switched ON (engine off or on).
1AD (Power supply)
I-Stop_ENG ST Ready/Cranking/Running/IS_Cond/IS_Stopping/IS_Stoped/IS_Rest art/IS_Restarting/IS_Running
NOTE:
  • Displays in the M-MDS but it does not operate.
LL_SW_D Lock/Unlock
  • Lock: Front door lock-link switch (LH) is in lock.
  • Unlock: Front door lock-link switch (LH) is in unlock.
  • 1A (CAN_L)
  • 1B (CAN_H)
LL_SW_D_LK Off/On
  • Off: Front door lock-link switch (LH) is in unlock.
  • On: Front door lock-link switch (LH) is in lock.
1U (Door lock (driver-side))
LL_SW_D_UNL Off/On
  • Off: Front door lock-link switch (LH) is in lock.
  • On: Front door lock-link switch (LH) is in unlock.
1V (Door unlock (driver-side))
LL_SW_P Lock/Unlock
  • Lock: Front door lock-link switch (RH) is in lock.
  • Unlock: Front door lock-link switch (RH) is in unlock.
  • 1A (CAN_L)
  • 1B (CAN_H)
LL_SW_P_UNL Off/On
  • Off: Front door lock-link switch (RH), rear door lock-link switch (LH), rear door lock-link switch (RH) is in unlock.
  • On: Front door lock-link switch (RH), rear door lock-link switch (LH), rear door lock-link switch (RH) is in lock.
1X (Door unlock (passenger-side and rear))
M_CL_CV_L Off/On
  • Off: Power liftgate (PLG) drive unit motor (LH) close is not operating.
  • On: Power liftgate (PLG) drive unit motor (LH) close is operating.
  • 2A (Liftgate open signal)
  • 2C (Liftgate close signal)
M_CL_CV_R Off/On
  • Off: Power liftgate (PLG) drive unit motor (RH) close is not operating.
  • On: Power liftgate (PLG) drive unit motor (RH) close is operating.
  • 2B (Liftgate close signal)
  • 2E (Liftgate open signal)
M_CL_L V Displays the voltage during a close operation of the power liftgate (PLG) drive unit motor (LH). -
M_CL_R V Displays the voltage during a close operation of the power liftgate (PLG) drive unit motor (RH). -
M_CNT_L - Displays the power liftgate (PLG) drive unit motor (LH) speed.
  • 1H (Hall effect switch No. 1)
  • 1J (Hall effect switch No. 2)
M_CNT_R - Displays the power liftgate (PLG) drive unit motor (RH) speed.
  • 1G (Hall effect switch No. 1)
  • 1I (Hall effect switch No. 2)
M_OP_CV_L Off/On
  • Off: Power liftgate (PLG) drive unit motor (LH) open is not operating.
  • On: Power liftgate (PLG) drive unit motor (LH) open is operating.
  • 2A (Liftgate open signal)
  • 2C (Liftgate close signal)
M_OP_CV_R Off/On
  • Off: Power liftgate (PLG) drive unit motor (RH) close is not operating.
  • On: Power liftgate (PLG) drive unit motor (RH) close is operating.
  • 2B (Liftgate close signal)
  • 2E (Liftgate open signal)
M_OP_L V Displays the current during a close operation of the power liftgate (PLG) drive unit motor (LH). -
M_OP_R V Displays the current during a close operation of the power liftgate (PLG) drive unit motor (RH). -
M_SEN_A_L Low/High
  • Low: Hall effect switch 2 (LH) pulse position is at LOW.
  • High: Hall effect switch 2 (LH) pulse position is at HI
1J (Hall effect switch No. 2)
M_SEN_A_R Low/High
  • Low: Hall effect switch 2 (RH) pulse position is at LOW.
  • High: Hall effect switch 2 (RH) pulse position is at HI
1I (Hall effect switch No. 2)
M_SEN_B_L Low/High
  • Low: Hall effect switch 1 (LH) pulse position is at LOW.
  • High: Hall effect switch 1 (LH) pulse position is at HI
1H (Hall effect switch No. 1)
M_SEN_B_R Low/High
  • Low: Hall effect switch 1 (RH) pulse position is at LOW.
  • High: Hall effect switch 1 (RH) pulse position is at HI
1G (Hall effect switch No. 1)
PB_STAT Off/On/Reserved/Unknown
  • Off: Electric parking brake switch is pressed.
  • On: Electric parking brake switch is pulled up.
  • Reserve d: -
  • Unknown: Electric parking brake switch signal is not determined.
  • 1A (CAN_L)
  • 1B (CAN_H)
PC_STAT IG OFF/ACC/IG ON/CRANK
  • IG OFF: Ignition is switched to OFF.
  • ACC: Ignition is switched to ACC.
  • IG ON: Ignition is switched ON (engine off or on).
  • CRANK: During engine cranking.
  • 1A (CAN_L)
  • 1B (CAN_H)
PLG_KEY Off/Open
  • Off: Power liftgate button of the remote transmitter is not pressed.
  • Open: Power liftgate button of the remote transmitter is pressed.
  • 1A (CAN_L)
  • 1B (CAN_H)
PLG_M_L A Displays the current during power liftgate (PLG) drive unit motor (LH) operation.
  • 2B (Liftgate close signal)
  • 2E (Liftgate open signal)
PLG_M_R A Displays the current during power liftgate (PLG) drive unit motor (RH) operation.
  • 2A (Liftgate open signal)
  • 2C (Liftgate close signal)
PLG_SW_D Off/On
  • Off: Power liftgate (PLG) front switch is not pressed.
  • On: Power liftgate (PLG) front switch is pressed.
1Y (Power liftgate (PLG) front switch signal (Input))
PLG_TRNS_OP Off/Open
  • Off: Open signal is not received from remote transmitter. (Power liftgate button of the remote transmitter is not pressed.)
  • Open: Open signal is received from remote transmitter. (Power liftgate button of the remote transmitter is pressed.)
  • 1A (CAN_L)
  • 1B (CAN_H)
PLG_TRNS_SP Off/Stop
  • Off: Stop signal is not received from remote transmitter. (Power liftgate button of the remote transmitter is not pressed.)
  • Open: Stop signal is received from remote transmitter. (Power liftgate button of the remote transmitter is pressed.)
  • 1A (CAN_L)
  • 1B (CAN_H)
RET_SW Off/On
  • Off: Return switch is off.
  • On: Return switch is on.
1T (Motor return signal)
SHIFT P/R/N/D/S(2)/L(1) Selector lever position signal from PCM
  • P: Selector lever is in P position.
  • R: Selector lever is in R position.
  • N: Selector lever is in N position.
  • D: Selector lever is in D position.
  • S(2): Selector lever is in D position 2nd gear.
  • L(1): Selector lever is in D position 1st gear.
  • 1A (CAN_L)
  • 1B (CAN_H)
T_SEN_L V Displays voltage at the power liftgate (PLG) touch sensor (LH) 1N (Power liftgate (PLG) touch sensor signal (LH))
T_SEN_R V Displays voltage at the power liftgate (PLG) touch sensor (RH) 1P (Power liftgate (PLG) touch sensor signal (RH))
VPWR_B V Displays voltage at the power supply
  • 1AA (Power supply)
  • 2I (Power supply)
VSS KPH, MPH Displays the vehicle speed signal from the PCM.
  • 1A (CAN_L)
  • 1B (CAN_H)