Diagnostic Procedure
DTC B1453:02 [POWER LIFTGATE (PLG) CONTROL MODULE] DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | INSPECT POWER LIFTGATE (PLG) LATCH SWITCH CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 8. | ||
| 2 | INSPECT POWER LIFTGATE (PLG) LATCH SWITCH GROUND CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Refer to appropriate wiring diagram and verify whether or not there is a common connector between power liftgate (PLG) latch switch terminal C and body ground. If there is a common connector:
If there is no common connector:
Go to Step 8. |
||
| 3 | INSPECT POWER LIFTGATE (PLG) CONTROL MODULE CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 8. | ||
| 4 | IINSPECT POWER LIFTGATE (PLG) LATCH SWITCH CIRCUIT FOR SHORT TO GROUND
|
Yes | Refer to appropriate wiring diagram and verify whether or not there is a common connector between the following terminals:
If there is a common connector:
If there is no common connector:
Go to Step 8. |
| No | Go to the next step. | ||
| 5 | INSPECT POWER LIFTGATE (PLG) LATCH SWITCH CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Go to the next step. |
| No | Refer to appropriate wiring diagram and verify whether or not there is a common connector between the following terminals:
If there is a common connector:
If there is no common connector:
Go to Step 8. |
||
| 6 | INSPECT POWER LIFTGATE (PLG) LATCH SWITCH CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Refer to appropriate wiring diagram and verify whether or not there is a common connector between the following terminals:
If there is a common connector:
If there is no common connector:
Go to Step 8. |
||
| 7 | INSPECT POWER LIFTGATE (PLG) LATCH SWITCH
|
Yes | Go to the next step. |
| No | Replace the power liftgate (PLG) latch switch, then go to the next step. (See LIFTGATE LATCH AND LOCK ACTUATOR REMOVAL/INSTALLATION .) |
||
| 8 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
Go to the next step. |
| No | Go to the next step. | ||
| 9 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [POWER LIFTGATE (PLG) CONTROL MODULE] .) |
| No | DTC troubleshooting completed. | ||