Required Procedure After Negative Battery Terminal Disconnection/Connection

System name Conditions after disconnecting the negative battery terminal Required procedure Reference
Before disconnecting negative battery terminal After connecting negative battery terminal
i-stop system (vehicle with i-stop) Specified information in the PCM cleared and the istop does not operate normally. - Perform battery condition initial setting (i-stop setting).(1) (See BATTERY CONDITION INITIALIZATION SETTING (i-stop SETTING) .)
Sunroof system Initial settings are reset, and operations are disabled. - Perform the initial settings of the sunroof system. (See SUNROOF SYSTEM INITIALIZATION PROCEDURE .)
(1) For vehicles with i-stop, if the negative battery terminal is disconnected and re-connected, battery condition initial setting (i-stop setting) must be performed.