EGR System - Diesel: Testing: TD-Signal
Using volt/ohmmeter, connect positive lead to terminal 2 of plug connection for TD input. Measure voltage at idle speed, should be approx. 2.8 volts. If not, check activation of RPM sensor for engine. If no activation, replace sensor.