CDI AC compressor shutoff, function - GF07.16-P-3010P
ENGINE 642 in MODEL 164.1 /8, 203.0 /2, 209.3 /4, 211.0 /2 /6, 219.3, 251.0 /1
ENGINE 642 in MODEL 463
Function requirements for the function refrigeration compressor shut-off is that the air conditioning is operating. The CDI control unit (N3/9) receives the message 'COMP_ON' (refrigerant compressor (A9) activated) via the Control Area Network Bus Class C (engine compartment) (CAN-C) from the EIS control unit (N73).
For the following conditions the CDI control unit interrupts actuation of the refrigerant compressor:
- Engine speed < 2000 RPM
- Value of the accelerator pedal sensor B37 > 95%
If the conditions for the function refrigerant compressor shut-off are no longer fulfilled then the refrigerant compressor is actuated again by the CDI control unit.