ME-SFI alternator interface function - GF07.61-P-3003M

ENGINE 275.950 in MODEL 215, 220 

ENGINE 275.951 in MODEL 230 up to Model Year 8 

ENGINE 275.953 in MODEL 216, 221 up to Model Year 8 

ENGINE 275.954 in MODEL 230 up to Model Year 8 

ENGINE 275.980 in MODEL 215, 220 

ENGINE 275.981 in MODEL 230 up to Model Year 8 

ENGINE 275.982 in MODEL 216, 221 up to Model Year 8 

ENGINE 285.950 in MODEL 240 

ENGINE 285.980 in MODEL 240 

Messages are exchanged between the ME-SFI [ME] control unit (N3/10) and alternator (G2) via the alternator interface which have the following tasks:

The ME-SFI [ME] control unit actuates the control response of the alternator via the alternator interface, in order, for example, to decrease the charging voltage when idling when the battery or onboard electrical system battery is sufficiently charged (G1). The reduced engine loading means that less fuel is consumed and the exhaust gas emissions improved.

"Terminal 61 signal" 

For alternators with an alternator, interface line "terminal 61" is not needed. From information which the ME-SFI [ME] control unit receives via the alternator interface, the "terminal 61 signal" is simulated in the ME-SFI [ME] control unit and is emitted via an output stage switching to ground (e.g. for the instrument cluster).

The alternator constantly performs self-diagnosis and sends the results when requested to the ME-SFI [ME] control unit. The ME-SFI [ME] control unit compares the results with other signals (e.g. engine speed, battery voltage and time after engine start) and detects the following faults:

IMPORTANTDiagnosis 

In order to check the regulation voltage the battery or on-board electrical system battery must be loaded using a battery testing device since the regulation voltage can be reduced significantly by a full and under no load battery or on-board electrical system battery.

The upper limit value for the regulation voltage can be up to 15 V.

ME-SFI [ME] control unit, location/task/ design/function GF07.61-P-5000M