ME-SFI alternator interface function - GF07.61-P-3003MIG

ENGINE 272.945 in MODEL 251.054/154 as of Model Year 2009/AEJ 08 

ENGINE 272.967 in MODEL 164.186 as of Model Year 2009/AEJ 08 MOPF 

ENGINE 272.967 in MODEL 251.056/065/156/165 as of Model Year 2009/AEJ 08 

ENGINE 273.923 in MODEL 164.871 as of Model Year 2009/AEJ 08 

ENGINE 273.963 in MODEL 164.172 as of Model Year 2009/AEJ 08 MOPF 

ENGINE 273.963 in MODEL 164.886, 251.072/172 as of Model Year 2009/AEJ 08 

Function requirements for the alternator interface, general points 

Alternator interface, general points 

Through the alternator interface, messages are exchanged over the drive LIN (LIN C1) between the alternator (G2) and the ME-SFI control unit (N3/10), in order to regulate the alternator control response. For this purpose, the ME-SFI control unit reads the following sensor and signal:

Alternator interface function sequence 

The ME-SFI control unit regulates the alternator control response, for example in order to reduce the regulation voltage (charging voltage) when the battery is sufficiently charged. This reduces engine load, thus also reducing fuel consumption and improving exhaust gas emissions.

The ME-SFI control unit controls the following functions:

The alternator constantly performs self-diagnosis and sends the results when requested to the ME-SFI [ME] control unit. This compares the results with other signals (for example, engine RPM, battery voltage, time since engine start) and thus detects any alternator faults.

The following faults are identified:

IMPORTANT Diagnosis

In order to check the regulation voltage, the battery must be placed under load using a battery tester since the regulation voltage can be reduced significantly when the battery is fully charged and under no load.

IMPORTANT "Terminal 61 signal"

For alternators with an alternator interface, line "terminal 61" is not needed. From information which the ME-SFI [ME] control unit receives via the alternator interface, the "terminal 61 signal" is simulated in the ME-SFI [ME] control unit and is emitted via an output stage switching to ground (e.g. for the instrument cluster).

REFER TO SYSTEM WIRING DIAGRAMS Electrical function schematic, alternator interface ME Model 164 PE07.61-P-2755-97MAA
Model 254 PE07.61-P-2755-97RAA
  ME-SFI [ME] control unit, component description N3/10 Engine 272 GF07.61-P-6000MIG 
N3/10 Engine 273 GF07.61-P-6000MLG