Sprinter III SCR Testing Using 05/15 XENTRY SW (TT 06/15-D)
Publication date: 2015-06-11Reference number: TT 06/15-D
SPRINTER III SCR TESTING USING 05/15 XENTRY SW
SPRINTER TECHNICAL TOPICS; JUNE 2015
Reference Number(s): TT 06/15, Date of Issue:
June 11, 2015
| SPRINTER: | Model 906 |
| GROUP: | 14.40 - Particulate trap |
CAUSE / EXPLANATION
When using Xentry SW 05/15 it has been reported that the NOx sensors never reach operational state, and the dosing valve test does not complete.
ACTION
The NOx sensors will become operational even though the setting never changes. Monitor your NOx sensor readings as usual. Perform dosing valve test with DAS by selecting Sprinter Up to 2013. If there are any other known tests that are not working properly, please report using XSF.