SCR Testing Notes (TT 12/15-B)
Publication date: 2015-12-10Reference number: TT 12/15-B
SCR TESTING NOTES
COMMERCIAL VANS TECHNICAL TOPICS; DECEMBER 2015
Reference Number(s): TT 12/15, Date of Issue:
December 10, 2015
| SPRINTER: | Model 906 |
| GROUP: | 14.40 - Particulate trap |
EXPLANATION
Dosing valve testing results and NOx sensor actual values.
NOTE:
This is an update from the November 2015 webcast.
ACTIONS
- Remember when performing the SCR dosing valve test ensure the SCR control unit has the latest software version installed otherwise the test results may be incorrect. Only with Xentry 09/2015 and the latest SCR control unit SW installed, the dosing test quantity has increased to 30 grams.
- As an update to the previously covered topic of the NOx sensor actual values for the operational status, the issue has been resolved with 09/2015 software with the 5153 add-on installed.