Battery Management System DTCS (BMS222PI)
BATTERY MANAGEMENT SYSTEM DTCS (BMS222PI)
| MB DTC | Description |
|---|---|
| B210A-00 | The power supply in the system is too low. |
| B210B-00 | The power supply in the system is too high. |
| P0562-00 | The on-board power supply voltage is too low. |
| P0563-00 | The on-board power supply voltage is too high. |
| P057F-00 | The values for the charge level of the high-voltage battery are implausible relative to each other. |
| P0605-00 | There is an internal control unit fault in the ROM memory. |
| P06B8-00 | There is an internal control unit fault in the NVRAM memory. |
| P0A0A-00 | The interlock circuit of the high-voltage on-board electrical system has an electrical fault. |
| P0A0B-00 | The interlock circuit of the high-voltage on-board electrical system has a malfunction. |
| P0A0C-00 | The interlock circuit of the high-voltage on-board electrical system has a short circuit to ground. |
| P0A0D-00 | The interlock circuit of the high-voltage on-board electrical system has a short circuit to positive. |
| P0A1F-00 | There is an internal fault in control unit ""Battery"". |
| P0A7E-00 | The high-voltage battery module has overtemperature. |
| P0A7F-00 | The age limit of the high-voltage battery module has been reached. |
| P0A95-00 | The electrical fuse for the high voltage has a malfunction. |
| P0A9C-00 | Temperature sensor A of the high-voltage battery has a malfunction. |
| P0A9D-00 | Temperature sensor A of the high-voltage battery has a short circuit to ground. |
| P0A9E-00 | Temperature sensor A of the high-voltage battery has a short circuit to positive. |
| P0AA1-00 | The 'positive pole' contact of contactor A in the high-voltage battery is stuck closed. |
| P0AA2-00 | The 'positive pole' contact of contactor A in the high-voltage battery is stuck open. |
| P0AA4-00 | The 'negative pole' contact of contactor A in the high-voltage battery is stuck closed. |
| P0AA5-00 | The 'negative pole' contact of contactor A in the high-voltage battery is stuck open. |
| P0AA6-00 | There is an isolation fault in the high-voltage on-board electrical system. |
| P0AA7-00 | The ohmmeter for isolation resistance in the high-voltage battery module has an electrical fault. |
| P0ABB-00 | Sensor A for battery voltage in the high-voltage battery module has a malfunction. |
| P0ABC-00 | Sensor A for battery voltage in the high-voltage battery module has a short circuit to ground. |
| P0ABD-00 | Sensor A for battery voltage in the high-voltage battery module has a short circuit to positive. |
| P0ABF-00 | Battery current sensor 'A' in the high-voltage battery module has an electrical fault. |
| P0AC0-00 | Battery current sensor 'A' in the high-voltage battery module has a malfunction. |
| P0AC2-00 | Battery current sensor 'A' in the high-voltage battery module has a short circuit to positive. |
| P0AC6-00 | Temperature sensor B of the high-voltage battery has a malfunction. |
| P0AC7-00 | Temperature sensor B of the high-voltage battery has a short circuit to ground. |
| P0AC8-00 | Temperature sensor B of the high-voltage battery has a short circuit to positive. |
| P0ACB-00 | Temperature sensor C of the high-voltage battery has a malfunction. |
| P0ACC-00 | Temperature sensor C of the high-voltage battery has a short circuit to ground. |
| P0ACD-00 | Temperature sensor C of the high-voltage battery has a short circuit to positive. |
| P0AD9-00 | Actuation of contact ""Positive terminal"" of the contactor in the high-voltage battery has an electrical fault or open circuit. |
| P0ADB-00 | The activation of the 'positive pole' contact of contactor A in the high-voltage battery has a short circuit to ground. |
| P0ADC-00 | The activation of the 'positive pole' contact of contactor A in the high-voltage battery has a short circuit to positive. |
| P0ADD-00 | Actuation of contact ""Negative terminal"" of the contactor in the high-voltage battery has an electrical fault or open circuit. |
| P0AE1-00 | The switch 'Precharging' in the high-voltage battery module has an electrical fault. |
| P0AE4-00 | The output for the 'precharge' switch on battery string A of the high-voltage battery module has an electrical fault or interruption. |
| P0AE9-00 | Temperature sensor D of the high-voltage battery has a malfunction. |
| P0AEA-00 | Temperature sensor D of the high-voltage battery has a short circuit to ground. |
| P0AEB-00 | Temperature sensor D of the high-voltage battery has a short circuit to positive. |
| P0B10-00 | Battery current sensor B in the high-voltage battery module has a short circuit to ground. |
| P0B11-00 | Battery current sensor B in the high-voltage battery module has a short circuit to positive. |
| P0B13-00 | The values of battery current sensors A and B in the high-voltage battery module are implausible relative to each other. |
| P0B15-00 | Battery voltage sensor B in the high-voltage battery module has a malfunction. |
| P0B16-00 | Battery voltage sensor B in the high-voltage battery module has a short circuit to ground. |
| P0B17-00 | Battery voltage sensor B in the high-voltage battery module has a short circuit to positive. |
| P0B1A-00 | Battery voltage sensor C in the high-voltage battery module has a malfunction. |
| P0B1B-00 | Battery voltage sensor C in the high-voltage battery module has a short circuit to ground. |
| P0B1C-00 | Battery voltage sensor C in the high-voltage battery module has a short circuit to positive. |
| P0B20-00 | Battery voltage sensor D in the high-voltage battery module has a short circuit to ground. |
| P0B21-00 | Battery voltage sensor D in the high-voltage battery module has a short circuit to positive. |
| P0B3C-00 | Sensor A for battery voltage of the high-voltage battery has a malfunction. |
| P0B3F-00 | Sensor A for battery voltage in the high-voltage battery has a malfunction. |
| P0B41-00 | Sensor B for battery voltage of the high-voltage battery has a malfunction. |
| P0B44-00 | Battery voltage sensor B in the high-voltage battery has a sporadic malfunction. |
| P0B46-00 | Sensor C for battery voltage of the high-voltage battery has a malfunction. |
| P0B49-00 | Battery voltage sensor C in the high-voltage battery has a sporadic malfunction. |
| P0B4B-00 | Sensor D for battery voltage of the high-voltage battery has a malfunction. |
| P0B4E-00 | Battery voltage sensor D in the high-voltage battery has a sporadic malfunction. |
| P0B50-00 | Sensor E for battery voltage of the high-voltage battery has a malfunction. |
| P0B53-00 | Battery voltage sensor E in the high-voltage battery has a sporadic malfunction. |
| P0B55-00 | Sensor F for battery voltage of the high-voltage battery has a malfunction. |
| P0B58-00 | Battery voltage sensor F in the high-voltage battery has a sporadic malfunction. |
| P0BC3-00 | Temperature sensor E of the high-voltage battery has a malfunction. |
| P0C78-00 | The pre-charging time on battery string A of the high-voltage on-board electrical system is too long. |
| P0CA6-00 | The charging current of the high-voltage battery is too high. |
| P0CA7-00 | The discharge current of the high-voltage battery is too high. |
| P0DAB-00 | The equalization of the cell voltages has a malfunction. |
| P0DE6-00 | The cell voltages of the high-voltage battery module are too low. |
| P0DE7-00 | The cell voltages of the high-voltage battery module are too high. |
| P0E2F-00 | Electrical fuse B for the high voltage has a malfunction. |
| P0E30-00 | Fuse 'N82/2f750 (Electrical fuse 750)' is defective. |
| P0E74-00 | There is a battery-internal isolation fault in the high-voltage battery module. |
| P1426-00 | There is a vehicle-side isolation fault in the high-voltage on-board electrical system. |
| P1428-00 | There is a vehicle-side isolation warning in the high-voltage on-board electrical system. |
| P1429-00 | There is a battery-internal isolation warning in the high-voltage battery module. |
| P142A-00 | There is a vehicle-side isolation alert in the high-voltage on-board electrical system. |
| P142C-00 | Sensor module A of the high-voltage battery module has an electrical fault. |
| P142D-00 | Sensor module B of the high-voltage battery module has an electrical fault. |
| P142E-00 | Sensor module C of the high-voltage battery module has an electrical fault. |
| P142F-00 | Sensor module D of the high-voltage battery module has an electrical fault. |
| P1430-00 | Sensor module E of the high-voltage battery module has an electrical fault. |
| P1431-00 | Sensor module F of the high-voltage battery module has an electrical fault. |
| P1433-00 | BATTERY DISCHARGING : There is an internal isolation fault in the high-voltage battery. |
| P1435-00 | The overvoltage protection in the high-voltage battery module is active. |
| P1614-00 | An internal control unit reset was performed. |
| P1A07-00 | The power supply of the sensor for battery current is outside the valid range. |
| P1B17-00 | The overload protection of switch 'Precharging' of the high-voltage battery is active. |
| P1C40-00 | Communication with the coolant pump of the high-voltage battery module has a malfunction. |
| P1C42-00 | Communication with coolant pump B of the high-voltage battery module has a malfunction. |
| P1C80-00 | The high-voltage component lockout is active. |
| P1CB4-00 | The power supply for circuit 30c has a malfunction. |
| P1CB6-00 | The power supply for circuit 30c is too high. |
| P1CB7-00 | The power supply for circuit 30c is too low. |
| P1CB8-00 | The power supply for circuit 30c is implausible. |
| P1CF5-00 | There is an isolation warning in the high-voltage on-board electrical system. |
| P1D28-00 | The frequency counter 'Switching cycles of contactors' of the high-voltage battery module has reached its final value. |
| P1D70-00 | Battery voltage sensor E in the high-voltage battery module has a short circuit to ground. |
| P1D71-00 | Battery voltage sensor E in the high-voltage battery module has a short circuit to positive. |
| P1D78-00 | The battery discharge protection function of the high-voltage battery module is activated. |
| U0076-00 | Hybrid CAN bus OFF error |
| U0100-00 | Communication with the control unit 'combustion engine' has a malfunction. |
| U0115-00 | Communication with control unit 'Drivetrain' has a malfunction. |
| U0141-00 | Communication with the front signal acquisition and actuation module has a malfunction. |
| U0155-00 | Communication with the instrument cluster has a malfunction. |
| U0168-00 | Communication with the electronic ignition lock has a malfunction. |
| U019B-00 | Communication with the on-board charger has a malfunction. |
| U01A0-00 | Internal communication of the high-voltage battery module with sensor module A has a malfunction. |
| U01A1-00 | Internal communication of the high-voltage battery module with sensor module B has a malfunction. |
| U01A2-00 | Internal communication of the high-voltage battery module with sensor module C has a malfunction. |
| U01A3-00 | Internal communication of the high-voltage battery module with sensor module D has a malfunction. |
| U01A4-00 | Internal communication of the high-voltage battery module with sensor module E has a malfunction. |
| U01A5-00 | Internal communication of the high-voltage battery module with sensor module F has a malfunction. |
| U0292-00 | Communication with control unit ""Electric machine B"" has a malfunction. |
| U0300-00 | An internal fault has occurred in the control unit software. |
| U105D-00 | Communication with the switchover valve in the coolant circuit of the high-voltage battery has a malfunction. |
| U3001-00 | The control unit was switched off improperly. |
| U3017-00 | The real-time internal control unit clock has a malfunction. |