LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2017 >> C300 Base, 2D Convertible >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Mixture Formation - 205 Chassis - 1 Of 2 >> Basic Knowledge >> Starting, Function >> Starting, Function - GF07.10-P-1001MRA
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Starting, Function - GF07.10-P-1001MRA

Engine 274.9 in model 205 (except 205.047/053/054/147/247/253) 

Engine 274.9 in model 253 (except 253.354/954) 

Starting function requirements, general points 

Starting, general points 

For starting, the ME-SFI [ME] control unit (N3/10) reads in the following signals:

The ME-SFI [ME] control unit actuates the following assembly parts to start the engine:

The ME-SFI [ME] control unit coordinates the injection and firing order during starting based on the signals from the crankshaft Hall sensor and the camshaft Hall sensors.

The starter control in the ME-SFI [ME] control unit takes on actuation and cutout of the starter.

Function sequence for start 

The starter control is subdivided into the following points:

Function sequence for start begin 

When the ignition key (transmitter key (A8/1)) is moved to the start position, the ME-SFI [ME] control unit receives the "Circuit 50 signal" from the powertrain control unit via the powertrain CAN and from the electronic ignition lock control unit via the chassis FlexRay.

The ME-SFI [ME] control unit uses a ground signal to actuate the starter circuit 50 relay (K40/8kH) on both sides. The power contact on the starter relay closes and the starter solenoid switch is supplied at "circuit 50" with voltage from "circuit 30".

Function sequence for start end 

Starter control is carried out automatically by the ME-SFI [ME] control unit (touch start). This means that once the start process is initiated, switching off "circuit 50" will have no further influence on the start procedure.

When engine cranking speed has reached 400 to 700 RPM, or after a starting time of 5 to 40 s (dependent on coolant temperature), the ME-SFI [ME] control unit interrupts the negative activation of the circuit 50 starter relay and thus terminates the starting procedure.

The starting procedure can only be aborted by switching off the ignition.

IMPORTANT A voltage dip limiter (R62) is installed at the positive battery terminal. Its task is to prevent a drop in the battery voltage below a defined voltage value during the starting procedure of the engine. This is performed through temporary limitation of the starter current. Note here that the battery voltage is only present at the starter positive line during the starting procedure. Before and after the start the starter-plus line must be free of tension otherwise the voltage dip limiter is defective.

  Electrical function schematic for starting   PE07.10-P-2701-97FBA
  Overview of system components for gasoline injection and ignition system with direct injection   GF07.70-P-9998MRA