LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2017 >> GLC300 Base >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Mixture Formation - 253 Chassis - 2 Of 4 >> Basic Knowledge >> Automatic start, basic function - GF07.10-P-1052A
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Automatic start, basic function - GF07.10-P-1052A

Engine all (CAR) 

General 

The engine starts automatically when the accelerator pedal is actuated or the brake pedal is released.

Function requirements 

Ignition ON (circuit 15)

Engine management ON (circuit 87 M)

Outside temperature between -10 and 40 °C

On-board electrical system battery temperature 0 to 60 °C

System diagnosis complete and fault-free

Function 

The automatic starting procedure takes place when the engine is in automatic stop and the ignition is still switched on. An automatic starting procedure takes place under the following conditions:

A voltage dip limiter on the positive pole of the on-board electrical system battery delays the voltage drop during the automatic starting procedure. The starting procedure ends once the engine reaches 400 to 700 RPM.

IMPORTANT The voltage dip limiter is an electrically switchable series resistor used to reduce the high power consumption of the starter when the engine is cranked. The voltage dip limiter is connected to the starter circuit 50 relay (M) via circuit 87. When the engine is started, voltage is supplied to the voltage dip limiter. This helps it recognize the starting procedure and activate the series resistor. If the on-board electrical system voltage drops too much due to the high power consumption of the starter, the voltage dip limiter switches the series resistor off.

IMPORTANT If the voltage drop at engine start is too large (U < 11 V), an automatic engine stop is not permitted for one minute so as to allow recharging of the ECO start/stop function auxiliary battery. The ECO start/stop function auxiliary battery is only switched in when the onboard electrical system voltage is high enough (U > 13 V). It is disconnected again when the alternator management is active or the on-board electrical system is severely overloaded.

IMPORTANT The start/stop unit operates using starter-assisted direct starting. After the engine stops, the crankshaft angle in the rest position is stored in the combustion engine control unit using the crankshaft angle sensor. When the engine starts, synchronization of the fuel injection system and the ignition system that is otherwise required is no longer necessary due to the stored crankshaft angle.

  Components Gearshift shaft position sensor, basic function Transmission 711.6 GF26.19-P-2000A