End Of Start, Basic Function - GF07.10-P-1033A

Engine All (4xWD) 

Engine All (CAR) 

Overview 

This document contains information on:

General 

The starter control is realized automatically by the combustion engine control unit.

Function 

The starting procedure ends if the engine has reached a rotational speed of 400 to 700 RPM or a starting time of approx. 5 to 40 s (depending on the coolant temperature). The powertrain control unit interrupts the negative activation to the circuit 50 starter relay. The starting procedure can only be interrupted by switching off the ignition.

IMPORTANT In the case of a repeated starting, a blocking time of approx. 1.5 to 3 s exists after the end of the starting procedure. This prevents the rotating pinion of the starter from meshing with the toothing of the engine drive plate.

  Control units     
  Combustion engine control unit, basic function   GF07.08-P-9890A