LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2018 >> S450 Base >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Mixture Formation - 222 Chassis (1 Of 3) >> Basic Knowledge >> Starting, Function >> Starting, Function - GF07.10-P-1001MNL
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Starting, Function - GF07.10-P-1001MNL

Engine 176.9, 177.9 in model 217 

Engine 176.9, 177.9 in model 222 

Engine 177.9 in model 290 

up to model year 2021 

Starting function requirements, general points 

Starting, general points 

For starting, the ME-SFI [ME] control unit (N3/10) reads in the following signals:

The ME-SFI [ME] control unit actuates the following assembly parts to start the engine:

The ME-SFI [ME] control unit coordinates the injection and firing order during starting based on the signals from the crankshaft Hall sensor and the camshaft Hall sensors.

The starter control in the ME-SFI [ME] control unit takes on actuation and cutout of the starter.

Function sequence for start 

The starter control is subdivided into the following points:

Function sequence for start begin 

Through actuation of the KEYLESS-GO start/top button (S2/3) (with code 889 (KEYLESS-GO)), the ME control unit receives the "circuit 50 signal" from the electronic ignition lock control unit via drive CAN, powertrain control unit, and suspension FlexRay.

The ME-SFI [ME] control unit uses a ground signal to actuate the starter circuit 50 relay (K40/8 kH) on both sides. The power contact on the starter relay closes and the starter solenoid switch is supplied at "circuit 50" with voltage from "circuit 30".

Function sequence for start end 

Starter control is carried out automatically by the ME-SFI [ME] control unit (touch start). This means that once the start process is initiated, switching off "circuit 50" will have no further influence on the start procedure.

When the engine cranking speed has reached approx. 400 to 700 rpm or a start time of approx. 5 to 40 s (depending on the coolant temperature), the ME-SFI control unit interrupts negative activation to the circuit 50 starter relay thereby ending the start procedure.

IMPORTANT When actuating the ignition key the starting procedure can only be aborted by switching off the ignition.

During the starting procedure with the KEYLESS-GO start/stop button, the engine start can be aborted by tapping the button again.

IMPORTANT A voltage dip limiter is installed at the positive battery terminal. Its task is to prevent a drop in the battery voltage below a defined voltage value during the starting procedure of the engine.

This is performed through temporary limitation of the starter current. Note here that a voltage of 12 V is present at the starter positive line only during the starting procedure.

  Electrical function schematic for starting Engine 177.9 in model 290 up to model year 2021 PE07.10-P-2701-97XBA
    Engine 176.9, 177.9 in model 217 Engine 176.9, 177.9 in model 222 PE07.10-P-2701-97SEL
  Overview of system components for gasoline injection and ignition system with direct injection   GF07.70-P-9998MNL