Power Window Relay
Apply 12 volts to the Blue and Light Green wire terminals on the power window relay. See WIRING DIAGRAMS . Measure voltage on Orange/Black wire terminal on the power window relay with the Black wire grounded. Measured voltage should be 12 volts. With the Black wire not connected to ground, no voltage should be present. Replace relay if operation is not as specified. See RELAY under REMOVAL & INSTALLATION.