Check For Short Between ABS Control Module & Hydraulic Solenoid Relay
- With ignition switch in OFF position, connect breakout box with adapter to ABS control module connector. Leave ABS control module disconnected. Disconnect hydraulic actuator assembly connector.
- Measure resistance of Brown wire between breakout box pin No. 28 and ground. Measure resistance of Green/Yellow wire between breakout box pin No. 35 and ground.
- If resistances are more than 10,000 ohms, go to PINPOINT TEST D13 . If resistances are less than 10,000 ohms, service wires in question between ABS control module and hydraulic actuator assembly.