2004 GENERATOR SPECIFICATIONS

Application Specification
Crown Victoria & Grand Marquis
Generator Amperage Rating (Maximum) 130 Amps
Load Test
With Tester Load (1) 87 Amps Minimum
Without Tester Load (2) (3)
No-Load Test (1) 13-15 Volts
Marauder
Generator Amperage Rating (Maximum) 120 Amps
Load Test
With Tester Load (1) 87 Amps
Without Tester Load (2) (3)
No-Load Test (1) 13-15 Volts
Police Intercepter
Generator Amperage Rating (Maximum) 200 Amps
Load Test
With Tester Load (1) 159 Amps
Without Tester Load (2) (3)
No-Load Test (1) 13-15 Volts
(1) All accessories off with engine running at 2000 RPM.
(2) Perform this test with engine running at 2000 RPM, A/C on, blower motor on high speed, and headlamps on high beam.
(3) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.