Instrument Cluster & Panel Illumination DTCS
SMART JUNCTION BOX (SJB) DIAGNOSTIC TROUBLE CODE (DTC) LIST
| DTC | Description | Action |
|---|---|---|
| B106E | Solid State Driver Disabled Due to Short Circuit | The module has temporarily disabled an output because an excessive current draw exists (such as a short to ground). The SJB cannot enable the output until the cause of the short is corrected. ADDRESS all other DTCs first. After the cause of the concern is corrected, CLEAR the DTCs. REPEAT the self-test. |
| B106F | Module Disabled Due to External Fault | The module has permanently disabled an output because an excessive current draw fault (such as a short to ground) has exceeded the limits that the SJB can withstand. The cause of the excessive current draw MUST be corrected before a new SJB is installed. ADDRESS all other DTCs first. After the cause of the concern is corrected, INSTALL a new SJB. TEST the system for normal operation. |
| B213A | Digital Dimmer Switch Input Circuit Failure | GO to PINPOINT TEST A . |
| B29B7 | White Lighting Output Circuit Open | If the backlighting components are inoperative, GO to PINPOINT TEST B . If the backlighting components are always on, GO to PINPOINT TEST C . |
| B29B8 | White Lighting Output Circuit Short to Ground | GO to PINPOINT TEST C . |
| B2A32 | LED Backlighting Output Circuit Open | If the backlighting components are inoperative, GO to PINPOINT TEST B . If the hardwired backlighting components are always on, GO to PINPOINT TEST C . |
| B2A33 | LED Backlighting Output Circuit Short to Ground | GO to PINPOINT TEST B . |
| All other DTCs | - | REFER to the Diagnostic Trouble Code (DTC) Chart in MULTIFUNCTION ELECTRONIC MODULES -- FUSION, MILAN & MKZ article. |