61 13... Crimping Micro QUADLOCK System Contacts (MQS)

WARNING: This page is about a different car, the 2010 BMW X5, 2009 BMW X5, 2008 BMW X5, and 2007 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

To crimp MQS contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 324 (2) from crimping set 61 4 320. 

NOTE: Pliers (1) open automatically as far as they will go when handles are pressed together.
Fig 1: Identifying Pliers 61 4 321
G04753309Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

Fold up contact carrier (2).

Insert MQS contact (3) in contact carrier (2).

Fold back contact carrier (2).

Fig 2: Identifying Pliers And Contact Carrier
G04753310Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Follow procedure for cutting and stripping insulation  from cables. See 61 13 CUTTING TO LENGTH AND STRIPPING INSULATION FROM CABLES .

Close pliers (1) one notch.

Insert stripped cable (2).

Close pliers (1) fully.

Fig 3: Identifying Pliers And Stripped Cable
G04753311Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

Open contact carrier (2) gently and carefully remove MQS contact.

NOTE: Check contact for correct crimping.
Fig 4: Opening Contact Carrier
G04753312Courtesy of BMW OF NORTH AMERICA, INC.