Servicing Precautions

WARNING: This page does not describe the selected car, but rather 34 other vehicles, including the 2001 BMW Z8, 2001 BMW Z3, 2001 BMW X5, 2001 BMW M5, and 2001 BMW M3. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: For location of DME and fuel pump relays, see DME & FUEL PUMP RELAY LOCATION  table under PRELIMINARY INSPECTION & ADJUSTMENTS.
  1. Ensure ignition is turned off before working on the ignition system. The engine may not be started without a connected secondary circuit. When checking compression, remove Digital Motor Electronics (DME) master relay.
  2. DO NOT connect shielded capacitors to terminal No. 1 of the ignition coil. DO NOT connect terminal No. 1 of the ignition coil to ground or battery positive terminal, as this will damage ignition stages in DME control unit.
  3. DO NOT connect DVOM or test light to terminal No. 1 of ignition coil while engine is running. High tension (350 volts) is present at coil terminal No. 4, secondary ignition leads, spark plugs and ignition coil terminal No. 1 to DME control unit.