61 35... Notes on ESD protection (Electro Static Discharge)

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2005 BMW 745i, 2005 BMW 745Li, 2004 BMW 745i, 2004 BMW 745Li, and 2003 BMW 745i. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

NOTE: Electrical components which are particularly sensitive to electrostatic discharge (electronic control units, sensors, etc.) are marked with the ESD warning symbol.

-Electro

-Static

-Discharge

For further information on this subject, please refer to Service Information SWZ 2 06 04 (128).

Statically charged persons can discharge by touching electrical components.

Fig 1: Showing Discharge
G03290864Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Humans can only detect a discharge starting from a level of approx. 3000 V.

The danger threshold for electrical components already starts from a level of approx. 100 V.

Fig 2: Showing Correct Way Of Handling Electrical Components
G03290865Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: Do not touch pins or multi-pin connectors directly! 
Touch electrical components by their housings only.
IMPORTANT: To prevent electrical components from being damaged or destroyed by electrostatic discharge, it is absolutely essential to comply with the following instructions:
  • When replacing electrical components, leave the replacement components in their original packaging until immediately before they are to be installed
  • If necessary, always return a removed component in its original packaging (always pack the component away immediately)
  • Read and comply with user information on using the associated ESD special tool 12 7 060