Closed-Circuit Current Measurement: Notes
Sporadically or continuously, an increased closed-circuit current can occur in the parked vehicle. Possible causes for that may be:
- An additional current consumer is connected to terminal 30 or the battery.
- Defective components, control units or control unit peripherals using too much power in sleep mode and preventing the vehicle entering sleep mode
- Automatic detection of the cause is not possible in the case of a closed-circuit current fault. On vehicles with an intelligent battery sensor, only the range of the quiescent current can be determined:
- Quiescent current less than 80 mA
- Quiescent current between 80 and 200 mA
- Quiescent current between 200 mA and 1 A
- Quiescent current above 1 A
Conclusions can be drawn as to the component causing the fault based on the amount by which the quiescent current limit is exceeded.