Home >> Mini >> 2012 >> Cooper Base, 2D Hatchback, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 1267 (Fuel System - Repair) >> Fuel Pump With Drive And Line >> 13 31...Notes On Fuel Pressure Check (Reference Pressure: Environment) >> Description of operation: pressure retaining function
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Description of operation: pressure retaining function

WARNING: This page does not describe the selected car, but rather 10 other vehicles, including the 2010 BMW M6, 2010 BMW M5, 2009 BMW M6, 2009 BMW M5, and 2008 BMW M6. However, it is still accessible from the selected car via links, so may be relevant.

The pressure regulator closes when the engine is at a standstill and the ignition key is in position 0. The fuel pressure in the delivery line is retained over an extended period. A non-return valve closes in the fuel pump. These measures help to retain the fuel pressure in the fuel system. Extended starting times are thus avoided.

Complaint: drive characteristic faults, lack of power 

If the measured value is less than the nominal value - 0.2 bar: 

If the measured value is greater than the nominal value + 0.2 bar: 

If no kinks are visible:

If measured value remains too high, then pressure regulator is in all probability faulty.

IMPORTANT: With less likelihood, the return line may be completely blocked. When the pressure regulator is removed, fuel could escape under pressure!

Complaint: starting problems 

Special tool 13 3 010 (hose clamp) is required for the following test.

If the measured value has dropped by more than 0.5 bar: 

If the measured value has now dropped by less than 0.5 bar, the following faults can be present: 

If the measured value has dropped by more than 0.5 bar again: 

NOTE:
  • All the fuel hoses and hose clips which were detached within the framework of the checks must be replaced.
  • Interrogate fault memory of DME control unit. Check stored fault messages. Rectify faults. Now clear the fault memory.