General notes

WARNING: This page does not describe the selected car, but rather 45 other vehicles, including the 2016 BMW M5, 2016 BMW 550i xDrive, 2016 BMW 550i, 2016 BMW 535i xDrive, and 2016 BMW 535i. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Caution - High Voltage Electrical System
G09908310Courtesy of BMW OF NORTH AMERICA, INC.
WARNING: Hybrid cars have an additional high-voltage electrical system which has its own safety regulations to be observed. Work on live high-voltage components is expressly prohibited. Prior to every operation which involves a high-voltage component, it is essential to disconnect the high-voltage system from the voltage supply and to secure it against unauthorized return to service.
  1. Switch off ignition.
  2. Remove the high-voltage safety connector.
  3. Prevent the high-voltage safety connector from being reinserted.
  4. Switch the ignition on.
  5. Always wait 10 seconds until the "High-voltage system switched off" Check Control message (ID 636) appears in the instrument cluster.
    Fig 2: Identifying High-Voltage Battery Handling Sign
    G09908311Courtesy of BMW OF NORTH AMERICA, INC.