61 13 ... Socket Housing (Radio Plug), Hybrid System MQS/MPQ

WARNING: This page is about a different car, the 2007 BMW 550i and 2006 BMW 550i. However, it is still accessible from the selected car via links, so may be relevant.

Manufactured by AMP:  The following contact types without strand sealing can be fitted in the plug housings:

Removing MPQ contacts from radio plug: 

Press lock (1) in direction of arrow.

Detach secondary lock (2) from radio plug.

Fig 1: Pressing Lock And Detaching Secondary Lock From Radio Plug
G00460753Courtesy of BMW OF NORTH AMERICA, INC.

Feed special tool 61 1 135 past side of contact.

Press special tool 61 1 135 in direction of arrow.

Pull wire (1) with socket contact out of radio plug (2).

Fig 2: Using Special Tool (61 1 135) To Remove Socket Contact From Radio Plug
G00460754Courtesy of BMW OF NORTH AMERICA, INC.

Removing MQS contacts from contact carrier: 

Press lock (1) in direction of arrow and pull housing (2) out of radio plug.

Fig 3: Pressing Lock To Remove Housing From Radio Plug
G00460755Courtesy of BMW OF NORTH AMERICA, INC.

Press lock (1) in direction of arrow. Pull contact carrier (2) out of housing (3).

NOTE:

When the contact carrier is pulled out, the secondary locks of the socket contacts are raised.

Fig 4: Identifying Lock, Contact Carrier, And Housing
G00460756Courtesy of BMW OF NORTH AMERICA, INC.

Hold down retaining hook (1) of socket contact in opening of contact carrier with a small screwdriver.

Pull wire with socket contact in direction of arrow as far as secondary lock (2).

NOTE:

The illustration shows an 8-pin socket housing where removal of the contacts is identical.

Fig 5: Identifying Retaining Hook And Secondary Lock
G00425997Courtesy of BMW OF NORTH AMERICA, INC.

Hold down arrester hook in secondary lock (1) again. Pull wire with socket contact (2) out of contact carrier (3).

Fig 6: Removing Cable With Socket Contact From Secondary Lock And Contact Carrier
G00425998Courtesy of BMW OF NORTH AMERICA, INC.

Removing MPQ contacts from contact carrier: 

Remove contact carrier (1) with MQS contacts from radio plug.

Raise lock (2) on radio plug.

Pull contact carrier (3) out of radio plug.

Fig 7: Identifying Contact Carriers And Lock
G00460757Courtesy of BMW OF NORTH AMERICA, INC.

Press lock (1) in direction of arrow.

Pull secondary lock (2) in direction of arrow completely out of contact carrier (3).

Fig 8: Identifying Lock, Secondary Lock, And Contact Carrier
G00460758Courtesy of BMW OF NORTH AMERICA, INC.

Press special tool 61 1 135 on inside of contact into contact carrier (2).

Pull wire with socket contact (1) out of contact carrier (2).

Fig 9: Using Special Tool (61 1 135) To Remove Socket Contact From Contact Carrier
G00460759Courtesy of BMW OF NORTH AMERICA, INC.