Nominal values
Observe the following setpoint values for the AUC sensor:
| Variable |
Value |
| Voltage range |
9 to 16.5 V |
| Overvoltage |
Greater than 18.5 V |
| Undervoltage |
Less than 8, 5 V |
| maximum power consumption |
less than 1 W |
| Response time |
Less than 1 s |
| Temperature range |
-40 to 85 deg C |