No Load Test

Connect starter in series with a 12-volt battery, a voltmeter and a 1000-amp ammeter. Compare readings with STARTER NO LOAD SPECIFICATIONS .

STARTER NO LOAD SPECIFICATIONS (1)

Application Max. Amps Min. RPM
Cordia, Precis & Tredia (2) 60 6500
Galant & Mirage 60 (3)
Montero
Automatic Transmission 60 6500
Manual Transmission 100 3000
Pickup
Manual Transmission 60 6500
Automatic Transmission 100 3000
Starion Turbo
Manual Transmission 60 6500
Automatic Transmission 100 3000
(1) Applied voltage of 11.5-12 volts.
(2) Except 2.0L with automatic transmission, which is 90 amps maximum at a minimum 3300 RPM.
(3) Manufacturer does not supply minimum RPM specification.