Checking The Terminal Resistance
- Disconnect the throttle position sensor connector.
- Measure resistance between the throttle position sensor side connector terminal No. 2 and terminal No. 3. Standard value is 2.0-4.0 kohm. See Fig 1 .
- Measure resistance between the throttle position sensor side connector terminal No. 1 and terminal No. 2. See Fig 2 . The normal condition allows the throttle valve to slowly open until fully open from the idle position. It changes smoothly in proportion to the opening angle of the throttle valve.
- If resistance is outside the standard value, or if it doesn't change smoothly, replace the throttle position sensor.
NOTE:
After replacement, the throttle position sensor should be adjusted.