Adjustment Procedures Of SWS Function < Vehicles With Keyless Entry System >: Notes
Required Special Tools:
- MB991223: Harness Set
- MB991958: Scan Tool (MUT-III Sub Assembly)
- MB991529: Diagnostic Trouble Code Check Harness
The following functions can be enabled or disabled by operating input switches in a special manner. This set mode is stored after the battery is disconnected.
- Keyless entry hazard answerback function
- Headlight automatic shutdown function
- Initialization of above mentioned functions
NOTE:
The keyless entry hazard answerback can be also adjusted by operating the RKE transmitter, (however, this adjustment can be done more easily by operating the transmitter.) Refer to ENABLING/DISABLING THE ANSWERBACK FUNCTION
.