ASC Off Switch Continuity Check
- As shown in the figure, connect the circuit tester to the ASC OFF switch as a single unit.
- Check the continuity status when the ASC OFF switch is pressed and when the switch is released.
Item When the ASC OFF switch is released (Not being operated) When the ASC OFF switch is pressed Continuity between terminal No. 2 and No. 5 No continuity Continuity exists (2 Ω or less) Continuity between terminal No. 3 and No. 4 Continuity exists Continuity exists