Example Of Abnormal Waveforms

NOTE:
  1. The size of the waveform patterns differs largely, depending on the adjustment of the variable knob on the oscilloscope.
  2. Identification of abnormal waveforms is easier when there is a large output current (regulator is not operating). (Waveforms can be observed when the headlights are illuminated).
  3. Check the conditions of the generator malfunction light (illuminated/not illuminated). Also, check the charging system totally.
ABNORMAL WAVEFORM PROBLEM CAUSE
Example 1
G06248639Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Open diode
Example 2
G06248640Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Short in diode
Example 3
G06248641Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Broken wire in stator coil
Example 4
G06248642Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Short in stator coil