Work Procedure
Perform the following procedures after replacing the multi-around monitor control unit.
- REPLACE MULTI-AROUND MONITOR CONTROL UNIT
Replace multi-around monitor control unit. Refer to REMOVAL AND INSTALLATION .
>>
GO TO 2.
- WRITING MAC KEY
Perform MAC key writing. Refer to DESCRIPTION .
>>
GO TO 3.
- PERFORM CONFIGURATION CAUTION: When before writing the multi-around monitor control unit configuration, always writing the MAC key.
Perform configuration. Refer to DESCRIPTION .
>>
GO TO 4.
- WRITING OF CALIBRATION DATA
Write the calibration data stored in the camera using M.U.T.-III SE. Refer to Work Procedure DIAGNOSIS PROCEDURE .
>>
GO TO 5.
- PERFORM SELF-DIAGNOSIS
- OPERATION CHECK
Confirm that the operation of the multi-around monitor and the camera image (reference line, expected route) are normal.
>>
WORK END