M.U.T-III Se Data Monitor Standard Value
NOTE:
The following table includes information (items) inapplicable to this vehicle. For information (items) applicable to this vehicle, refer to M.U.T-III SE display items.
| Monitor item | Condition | Value/Status (Approx.) |
|---|---|---|
| Range position | Shift position: P position | P |
| Shift position: R position | R | |
| Shift position: N position | N | |
| Shift position: D position | D | |
| Shift position judgment | Selector lever: H position | H |
| Selector lever: R position | R | |
| Selector lever: D/M position | D | |
| Selector lever: Nr position | Nr | |
| Selector lever: Nd position | Nd | |
| Target shift position | Shift position: P position | P |
| Shift position: N position | R | |
| Shift position: R position | N | |
| Shift position: D position | D | |
| Actual shift position | CVT position: P position | P |
| CVT position: N position | R | |
| CVT position: R position | N | |
| CVT position: D position | D | |
| Vehicle state | Ignition switch is ON (Engine is stopped) | State3 |
| While engine starting | State4 | |
| Engine started | State5 | |
| Shift sensor 1 | Selector lever is held in H (Home), R, and Nr positions | On |
| Other than the above | Off | |
| Shift sensor 2 | Selector lever is held in H (Home), R, and Nr positions | On |
| Other than the above | Off | |
| Shift sensor 3 | Selector lever is held in H (Home) and Nr positions | On |
| Other than the above | Off | |
| Shift sensor 4 | Selector lever is held in H (Home), Nr, and Nd positions | On |
| Other than the above | Off | |
| Shift sensor 5 | Selector lever is held in H (Home), Nr, and Nd position | On |
| Other than the above | Off | |
| Shift sensor 6 | Selector lever is held in H (Home) and Nd positions | On |
| Other than the above | Off | |
| Shift sensor 7 | Selector lever is held in H (Home), D/M, and Nd positions | On |
| Other than the above | Off | |
| Shift sensor 8 | Selector lever is held in H (Home), D/M, and Nd positions | On |
| Other than the above | Off | |
| Shift switch 1 | P position switch is pressed | On |
| Other than the above | Off | |
| Shift switch 2 | P position switch is pressed | Off |
| Other than the above | On | |
| Power supply relay A | Ignition switch is ON | On |
| Power supply relay B | Ignition switch is ON | On |
| Ignition switch | Ignition switch is ON | On |
| Power supply voltage | Battery voltage: Less than 8.97 V | Low |
| Battery voltage: 8.97 V or more to 10.8 V or less | Low/Normal | |
| Battery voltage: More than 10.8 V | Normal | |
| ECU power 1 | 10 V or more | HIGH LEVEL |
| 7 V or less | LOWER LEVEL | |
| Main power voltage | Ignition switch is ON | 9-16V |
| ECU power 2 | 10 V or more | HIGH LEVEL |
| 7 V or less | LOWER LEVEL | |
| Motor A U voltage | No shifting | 9-16V |
| Motor A V voltage | No shifting | 9-16V |
| Motor AW voltage | No shifting | 9-16V |
| Motor B U voltage | No shifting | 9-16V |
| Motor B V voltage | No shifting | 9-16V |
| Motor BW voltage | No shifting | 9-16V |
| Shift sensor 1 voltage | Selector lever is held in H (Home), R, and Nr positions | 1.08-2.12 V |
| Other than the above | 2.68-3.28 V | |
| Shift sensor 2 voltage | Selector lever is held in H (Home), R, and Nr positions | 1.08-2.12 V |
| Other than the above | 2.68-3.28 V | |
| Shift sensor 3 voltage | Selector lever is held in H (Home) and Nr positions | 1.08-2.12 V |
| Other than the above | 2.68-3.28 V | |
| Shift sensor 4 voltage | Selector lever is held in H (Home), Nr, and Nd positions | 1.08-2.12 V |
| Other than the above | 2.68-3.28 V | |
| Shift sensor 5 voltage | Selector lever is held in H (Home), Nr, and Nd positions | 1.08-2.12 V |
| Other than the above | 2.68-3.28 V | |
| Shift sensor 6 voltage | Selector lever is held in H (Home) and Nd positions | 1.08 - 2.12 V |
| Other than the above | 2.68 - 3.28 V | |
| Shift sensor 7 voltage | Selector lever is held in H (Home), D/M, and Nd positions | 1.08 - 2.12 V |
| Other than the above | 2.68 - 3.28 V | |
| Shift sensor 8 voltage | Selector lever is held in H (Home), D/M, and Nd positions | 1.08 - 2.12 V |
| Other than the above | 2.68 - 3.28 V | |
| Shift switch 1 voltage | P position switch is pressed | 1.08 - 2.12 V |
| Other than the above | 2.68 - 3.28 V | |
| Shift switch 2 voltage | P position switch is pressed | 2.68 - 3.28 V |
| Other than the above | 1.08 - 2.12 V |