DTC Confirmation Procedure
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 5 seconds before conducting the next test.
TESTING CONDITION:
- Engine coolant temperature and EGR temperature must be verified in "DATA MONITOR" mode with CONSULT-II before starting DTC WORK SUPPORT test. If it is out of range below, the test cannot be conducted.
COOLAN TEMP/S: -10 to 40°C (14 to 104°F)*
EGR TEMP SEN: Less than 4.8V
If the values are out of the ranges indicated above, park the vehicle in a cool place and allow the engine temperature to stabilize. Do not attempt to reduce the engine coolant or EGR temperature with a fan or means other than ambient air. Doing so may produce an inaccurate diagnostic result.
*: Although CONSULT-II screen displays "-10 to 40°C (14 to 104°F)" as a range of engine coolant temperature, ignore it.
WITH CONSULT-II
- Turn ignition switch OFF and wait at least 5 seconds, then turn ignition switch ON.
- Select "EGR SYSTEM P1402" of "EGR SYSTEM" in "DTC WORK SUPPORT" mode with CONSULT-II.
- Touch "START". Follow instruction of CONSULT-II.
- Start engine and let it idle until "TESTING" on CONSULT-II screen is turned to "COMPLETED". (It will take 60 seconds or more.)
If "TESTING" is not displayed after 5 minutes, turn ignition OFF and cool the engine coolant temperature to the range of - 10 to 40°C (14 to 104°F). Retry from step 1 .
- Make sure that "OK" is displayed after touching "SELF-DIAG RESULTS". If "NG" is displayed, refer to "DIAGNOSTIC PROCEDURE ".
WITH GST
- Turn ignition switch ON and select MODE 1 with GST.
- Check that engine coolant temperature is within the range of - 10 to 40°C (14 to 104°F).
- Check that voltage between ECM terminal 63 (EGR temperature sensor signal) and engine ground is less than 4.8V.
- Start engine and let it idle for at least 60 seconds.
- Stop engine.
- Perform from step 1 to 4.
- Select MODE 3 with GST.
- If 1st trip DTC is detected, go to "DIAGNOSTIC PROCEDURE ".