Limit Switch Circuit Check Front RH
- CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH LIMIT SIGNAL
- Turn ignition switch ON.
- Check voltage between power window motor RH connector D105 terminal 15 and ground.TERMINAL VOLTAGE CONDITION CHART
Connector Terminals Condition Voltage (V) (Approx.) (+) (-) D105 15 Ground Front door window RH is between fully-open and just before fully-closed position (ON) 0 Front door window RH is between just before fully closed position and fully closed position (OFF) 5
OK or NG
OK: Limit switch circuit is OK.
NG: GO TO 2.
- CHECK LIMIT SWITCH GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect front power window motor RH.
- Check continuity between front power window motor RH connector D104 terminal 6 and ground.
6 - Ground : Continuity should exist.
OK or NG
OK: Replace front power window motor RH. Refer to "REMOVAL AND INSTALLATION ".
NG: GO TO 3.
- CHECK HARNESS CONTINUITY
- Disconnect power window and door lock/unlock switch RH.
- Check continuity between power window and door lock/unlock switch RH connector and front power window motor RH connector.TERMINAL CONTINUITY REFERENCE CHART
Connector Terminal Connector Terminal Continuity A B Power window and door lock/unlock switch RH: D105 3 Front power window motor RH: D104 6 Yes - Check continuity between front power window motor RH connector and ground.TERMINAL CONTINUITY REFERENCE CHART
Connector Terminal Ground Continuity B Front power window motor RH: D104 6 No
OK or NG
OK: GO TO 4.
NG: Repair or replace harness.
- CHECK HARNESS CONTINUITY
- Check continuity between power window and door lock/unlock switch RH connector and front power window motor RH connector.TERMINAL CONTINUITY REFERENCE CHART
Connector Terminal Connector Terminal Continuity A B Power window and door lock/unlock switch RH: D105 15 Front power window motor RH: D104 5 Yes - Check continuity between front power window motor RH connector and ground.TERMINAL CONTINUITY REFERENCE CHART
Connector Terminal Ground Continuity B Front power window motor RH: D104 5 No
OK or NG
OK: GO TO 5.
NG: Repair or replace harness.
- Check continuity between power window and door lock/unlock switch RH connector and front power window motor RH connector.
- CHECK LIMIT SWITCH GROUND
Check continuity between power window and door lock/unlock switch RH connector and ground.
TERMINAL CONTINUITY REFERENCE CHARTConnector Terminal Ground Continuity Power window door lock/unlock switch RH: D105 3 Yes Fig 5: Checking Continuity Between Power Window And Door Lock/Unlock Switch RH Connector Terminal 3 And GroundCourtesy of NISSAN MOTOR CO., U.S.A.
OK or NG
OK: GO TO 7.
NG: GO TO 6.
- CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH GROUND CIRCUIT
Check continuity between power window and door lock/unlock switch RH connector D105 terminal 11 and ground.
11 - Ground : Continuity should exist.
OK or NG
OK: Replace power window and door lock/unlock switch RH. Refer to "FRONT DOOR ".
NG: Repair or replace harness.
- CHECK FRONT POWER WINDOW MOTOR RH LIMIT SIGNAL
- Connect power window and door lock/unlock switch RH and front power window motor RH.
- Turn ignition switch ON.
- Check voltage between power window and door lock/unlock switch RH connector.TERMINAL VOLTAGE CONDITION CHART
Connector Terminals Condition Voltage (V) (Approx.) (+) (-) Power window and door lock/unlock switch RH: D105 15 3 Front door window RH is between fully-open and just before fully-closed position (ON) 0 Front door window RH is between just before fully closed position and fully closed position (OFF) 5
OK or NG
OK: Check the condition of the harness and connector.
NG: Replace front power window motor RH. Refer to "REMOVAL AND INSTALLATION ".