  1. CHECK WARNING LAMP ILLUMINATION 
    1. Turn ignition switch ON.
    2. Make sure that warning lamps (such as MIL and oil pressure warning lamp) illuminate.

    Do warning lamps illuminate? 

    YES >> GO TO 2.

    NO >> Check ignition power supply system of combination meter. Refer to , "POWER SUPPLY AND GROUND CIRCUIT INSPECTION  ".

  2. CHECK SELF-DIAGNOSIS OPERATION 

    Perform combination meter self-diagnosis. Refer to "SELF-DIAGNOSIS FUNCTION  ".

    Does self-diagnosis function operate? 

    YES: >> GO TO 3.

    NO >> Check battery power supply of combination meter and ground system. Refer to "POWER SUPPLY AND GROUND CIRCUIT INSPECTION  ".

  3. CHECK ODO/TRIP METER OPERATION 

    Check segment display status of odo/trip meter. Refer to "SELF-DIAGNOSIS FUNCTION  ".

    Fig 1: Checking ODO/ Meter Display Status
    G02023675Courtesy of NISSAN MOTOR CO., U.S.A.

    Is the display normal? 

    YES >> GO TO 4.

    NO >> Replace combination meter.

  4. CHECK FUEL WARNING LAMP ILLUMINATION 

    During fuel warning lamp check, confirm illumination of fuel warning lamp.

    Fig 2: Checking Fuel Warning Lamp Illumination
    G02023676Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    OK >> GO TO 5.

    NG >> Replace combination meter.

  5. CHECK METER CIRCUIT 

    Check indication of each meter/gauge in self-diagnosis mode. Refer to "SELF-DIAGNOSIS FUNCTION  ".

    Fig 3: Checking Indication Of Each Meter/Gauge In Self-Diagnosis Mode
    G02023677Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    OK >> GO to diagnosis results. Refer to "DIAGNOSIS RESULTS  ".

    NG >> Replace combination meter.