Trunk Release Solenoid Check
- CHECK TRUNK LID OPENER
Check trunk release operation with trunk lid opener switch.
NOTE: First check trunk lid opener cancel switch position. Refer to , "TRUNK LID OPENER ".Does trunk lid open?
Yes: GO TO 2.
No: Check trunk release solenoid and the circuit.
- CHECK TRUNK LID OPENER ACTUATOR OPERATION
With CONSULT-II
- Select "ACTIVE TEST" in "MULTI REMOTE ENT" with CONSULT-II.
- Select "TRUNK/BACK DOOR" and touch "ON".
Trunk release solenoid should operate.
NOTE: If CONSULT-II is not available, skip this procedure and go to the next step.
OK or NG
OK: Trunk lid opener actuator circuit is OK.
NG: Check harness for open or short between BCM and trunk lid opener actuator.
- CHECK TRUNK LID OPENER ACTUATOR CIRCUIT
Without CONSULT-II
- Disconnect trunk lamp switch and trunk release solenoid connector.
- While pressing keyfob release button, check voltage between trunk lamp switch and trunk release solenoid harness connector B32 terminal 3 and ground.
3 - Ground: Battery voltage should exist.
- Check continuity between trunk lamp switch and trunk release solenoid harness connector B32 terminal 4 and ground.
4 - Ground: Continuity should exist.
OK or NG
OK: Replace trunk release solenoid.
NG: Check the following:
- Harness for open or short between BCM and trunk release solenoid
- Harness for open or short between trunk lamp switch and trunk release solenoid and ground
- Replace BCM