Check that other systems using the signal of the following systems operate normally.

TROUBLE DIAGNOSES SYMPTOM CHART

Symptom Repair order
None of the power windows can be operated using any switch 1. BCM POWER SUPPLY AND GROUND CIRCUIT CHECK
2. MAIN POWER WINDOW AND DOOR LOCK/UNLOCK POWER SUPPLY AND GROUND CIRCUIT CHECK 
3. Replace main power window and door lock/unlock switch. See DOOR FINISHER
Front power window LH alone does not operate 1. FRONT POWER WINDOW LH CIRCUIT CHECK 
2. Replace main power window and door lock/unlock switch. See DOOR FINISHER
Front power window RH alone does not operate from power window and door lock/unlock switch RH 1. FRONT POWER WINDOW RH CIRCUIT CHECK (POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OPERATION) 
Front power window RH alone does not operate from main power window and door lock/unlock switch 1. MAIN POWER WINDOW AND DOOR LOCK/UNLOCK POWER SUPPLY AND GROUND CIRCUIT CHECK 
2. FRONT POWER WINDOW RH CIRCUIT CHECK (MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OPERATION) 
Rear power window LH alone does not operate from rear power window switch LH 1. REAR POWER WINDOW LH CIRCUIT CHECK (REAR POWER WINDOW SWITCH LH OPERATION) 
Rear power window LH alone does not operate from main power window and door lock/unlock switch 1. REAR POWER WINDOW LH CIRCUIT CHECK (MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OPERATION) 
Rear power window RH alone does not operate from rear power window switch RH 1. REAR POWER WINDOW RH CIRCUIT CHECK (REAR POWER WINDOW SWITCH RH OPERATION) 
Rear power window RH alone does not operate from main power window and door lock/unlock switch 1. REAR POWER WINDOW RH CIRCUIT CHECK (MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OPERATION) 
Power window retained power operation does not operate properly 1. CHECK THE RETAINED POWER OPERATION MODE SETTING .
2. DOOR SWITCH CHECK 
3. Replace BCM. See REMOVAL AND INSTALLATION OF BCM .