Component Function Check
- PRECONDITIONING
TESTING CONDITION:
- Before performing the following procedure, confirm that battery voltage is more than 12.8V at idle.
- Before performing the following procedure, confirm that all load switches and A/C switch are turned OFF.
GO TO 2.
- PERFORM COMPONENT FUNCTION CHECK
With CONSULT-III
- Start engine and let it idle.
- Select "BAT CUR SEN" in "DATA MONITOR" mode with CONSULT-III.
- Check "BAT CUR SEN" indication for 10 seconds.
"BAT CUR SEN" should be above 2, 300 mV at least once.
Without CONSULT-III
- Start engine and let it idle.
- Check voltage between ECM harness connector terminals under the following conditions.TERMINALS VOLTAGE REFERENCE
ECM Ground Voltage (V) Connector Terminal F8 42 (Battery current sensor signal) Ground Above 2.3 at least once Is the inspection result normal?
YES: INSPECTION END
NO: Go to "DIAGNOSIS PROCEDURE "