Component Inspection
- CHECK POWER SWITCH (PUSH SWITCH)
- Turn power switch OFF.
- Disconnect power switch connector.
- Check continuity between power switch terminals.TERMINALS CONTINUITY REFERENCE CHART
Power switch Condition Continuity Terminal 8 4 Pressed Existed Not pressed Not existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace power switch.