Component Inspection
- CHECK THROTTLE POSITION SENSOR
- Turn ignition switch OFF.
- Reconnect all harness connectors disconnected.
- Perform "Throttle Valve Closed Position Learning". Refer to "WORK PROCEDURE ".
- Turn ignition switch ON.
- Shift selector lever position to D.
- Check the voltage between ECM harness connector terminals under the following conditions.
ECM Condition Voltage + - Connector Terminal Connector Terminal F8 37 (TP sensor 1 signal) F8 36 (Sensor ground) Accelerator pedal Fully released More than 0.36 V Fully depressed Less than 4.75 V 38 (TP sensor 2 signal) Fully released Less than 4.75 V Fully depressed More than 0.36 V Is the inspection result normal?
YES: INSPECTION END
NO: Replace electric throttle control actuator. Refer to "REMOVAL AND INSTALLATION ".