"P-SHIFT" Warning Lamp Check
- CHECK WARNING LAMP OPERATION
With CONSULT
- Check "INDICATOR" in "ACTIVE TEST" mode with CONSULT.
- Select "KNOB ON".
"P-SHIFT" warning lamp should illuminate.
Without CONSULT
- Turn ignition switch OFF.
- While monitoring the combination meter warning lamps, turn ignition switch ON. "P-SHIFT" warning lamp should illuminate for 1 second to perform a bulb check.
OK or NG
OK: Inspection end.
NG: Check combination meter. Refer to COMBINATION METERS .