Pull-In Winding

Check in same manner as Hold-In Winding Test, except connect ammeter and voltmeter between solenoid switch terminal and solenoid motor (M or MOT) terminal.

CAUTION: Do not leave pull-in winding energized more than 15 seconds.

Current draw will decrease as winding temperature increases.