Intermittent Test
Monitor a TECH 1 while moving related connectors and wiring harness. if the failure is induced, the scan data will change from LO to HI or HI to LO. Moving the gear slowly through each gear position while monitoring the PRNDL switch with the TECH 1 may locate a faulty switch. This may help isolate the location of the malfunction.