No Keyless Entry Features Operate
- If power door locks do not operate properly, see appropriate DOOR LOCKS - POWER article in this section. If power door locks operate properly, disconnect keyless entry receiver connector. Connect test light between keyless entry receiver connector C2 terminal "A" (Orange wire) and ground, then between connector C1 terminal "A" (Orange wire) and ground.
- If test light does not light, check Orange wire for an open circuit. If test light lights, connect test light between module connector C2 terminal "A" (Orange wire) and terminal "H" (Black wire). If test light does not light, check Black wire for an open circuit.
- If test light lights, turn ignition switch to RUN position. Connect test light between module connector C1 terminal "B" (Pink wire) and "H" (Black wire). If test light does not light, check Pink wire for an open circuit. If test light lights, check for poor connection. If connection is okay, replace remote keyless entry module.